(12) #6 VERT. FULL HEIGHT EA. FA. TILT PANEL PER PLAN INTERIOR FACE PER T2 SHEETS / ARCH. OPENING PER T2 SHEETS/ARCH. EXTERIOR FACE (TYP.) 1" CLR. #3 TIES W/ SEISMIC HOOKS FULL HEIGHT OF WALL. TIES ARE TO BE AT 2 1/2" SPA. FROM BOTTOM OF PANEL UP TO A MINIMUM OF 4'-0" ABOVE THE TOP OF OPENING AT WHICH POINT THE SPACING CAN BE INCREASED TO 6" TILT PANEL PER PLAN INTERIOR FACE PER T2 SHEETS / ARCH. OPENING PER T2 SHEETS/ARCH. EXTERIOR FACE (TYP.) 1" CLR. (TYP.) 1 3/4" CLR. (6) #6 VERT. FULL HEIGHT EA. FA. #3 TIES @ 6" SPA. W/ SEISMIC HOOKS FULL HEIGHT OF WALL CROSSTIES PER ACI REQUIREMENTS - ALTERNATE SIDE THAT SEISMIC HOOK OCCURS ON CROSSTIES PER ACI REQUIREMENTS - ALTERNATE SIDE THAT SEISMIC HOOK OCCURS ON (TYP.) 2" CLR. (TYP.) 2" CLR. CLR. 1 3/4" T4.1 1 1/2" = 1'-0"