1 3/4" THICK T-PLATE W/ 3/4" THICK GUSSET - COORD. LENGTH & WIDTH REQUIREMENTS W/ JOIST GIRDER MANUF. GRID TILT PANEL PER PLAN EMBED PL. EP-6 PER PLATE KEY J.B.E. JOIST GIRDER PER PLAN ROOF SHEATHING PER PLAN DO NOT WELD JOIST GIRDER BOTTOM CHORD TO STABILIZER PL. EMBED PL. EP-1 PER PLATE KEY CONT. 6x BLOCKING 1/4 5/16 CONT. L8X6X1/2 (EMBED PL. A-1 PER PL. KEY) - FASTEN STRAP AND SHEATHING TO STEEL USING HILTI X-U POWDER ACTUATED FASTENERS - MATCH NAILING PATTERN AND SPACING SHOWN ON 01S2.3 - COPE & SPLICE @ GIRDER LOCATIONS PROVIDE 18 GA X 4" WIDE STRAP ON TOP OF SHEATHING - FASTEN STRAP AND SHEATHING TO STEEL USING HILTI X-U POWDER ACTUATED FASTENERS - MATCH NAILING PATTERN AND SPACING SHOWN ON 01S2.3 - ALL SHEATHING FASTENERS ARE TO BE INSTALLED THRU STRAP AND INTO WOOD SHEATHING AND STRUCTURE BELOW 1'-6" MIN.