OPENING PER PLAN SHEATHING PER PLAN CONT. 3X PL. ON TOP OF JOIST FRAMING PER PLAN (TYP.) PROVIDE 4X6 EA. SIDE OF OPENING (TYP.) PER ARCH. ( 4'-0" MAX.) FULL WIDTH BTW. JOIST TYP. ROOF PURLINS PER PLAN (TYP.) AT EACH CORNER OF OPENING, PROVIDE SIMPSON CMST12 COIL STRAP (OR EQ.) PARALLEL TO PURLINS AS SHOWN - FASTEN TO BLOCKING AND TO 4X WITH (36) 16d NAILS ((72) TOTAL NAILS PER STRAP) PROVIDE DOUBLE BLOCKING / PURLINS AS REQUIRED TO ALLOW FOR ATTACHMENT OF STRAPPING AS SHOWN (TYP.) PROVIDE SIMPSON HANGERS FOR ALL WOOD-TO-WOOD AND WOOD-TO- PLATE CONNECTIONS - INSTALL PER MANUF. RECOMM. (TYP.) NOTES: 1.) REFER TO ARCH. DRAWINGS FOR EXACT LOCATIONS OF HOODS. 2.) ANCHOR HOODS TO WOOD FRAMING AS SPECIFIED BY THE EQUIPMENT MANUF. 3.) G.C. OPTION TO PROVIDE STRAPS THAT GO FULL WIDTH OF OPENING IN LIEU OF SEPERATE STRAPS AS SHOWN.