GYP. PER ARCH. (TYP.) WALL FRAMING PER ARCH. NOTE: REFER TO HEADER SCHEDULE & TYP. DETAILS FOR SUPPORT @ JAMBS JOIST PER PLAN CONT. 43 MIL TRACK - FASTEN TO EA. STUD W/ MIN. (2) #10 S.D.S.T. SCREWS TOP OF WALL PER ARCH. (2) CONT. 600S162-43 W/ 43 MIL TOP TRACK - FASTEN TO CONT. TRACK W/ (2) #10 S.D.S.T. SCREW @ 8" SPA. FASTEN JOIST TO TRACK W/ 12 GA. x 4" LONG CLIP ANGLE (SIMPSON LSSC4.25 OR EQ.) -FASTEN EA. LEG TO FRAMING W/ (4) #10 S.D.S.T. SCREWS BLOCKING BTW. STUDS TO MATCH WALL STUD SIZE - FASTEN TO CONT. TRACK W/ (1) #10 S.D.S.T. SCREW @ 8" MAX SPA. FASTEN BLOCKING TO GYPSUM AS REQUIRED PER SHEARWALL SCHEDULE NOTE: G.C. ALTERNATE TO PROVIDE TALLER STUDS AT THESE AREAS IN LIEU OF BOXED MEMBER AS SHOWN ON TOP. CONT. 43 MIL TRACK -FASTEN TO EA. STUD W/ MIN. (4) #10 S.D.S.T. SCREWS