5/16 ATTACHMENT ANGLE - PER THIS DETAIL EMBED ANGLE: L5x3 -1/2x5/16 x 10" LONG w/ (2) 3/4"Ø x6" HSA EMBED ANGLE - SEE ABV 5/16" L5x3-1/2x5/16 x 5" LONG w/ (2) 5/8" DIA x 32" DBA AND (1) 3/4" DIA. x 6" HSA. TYP 1 1/2" NON-SHRINK GROUT CONC TILT-UP PANEL 1 1/2" NON-SHRINK GROUT CONC TILT-UP PANEL ATTACH DBA TO ANGLE w/ FULL FUSION WELD PANEL JOINT AND SEALANT, SEE ARCH 1'-0" 1'-0" NOTE: PROVIDE TYPICAL PANEL JOINT EMBED AT ALL PANEL JOINTS AND PANEL ENDS UNLESS NOTED OTHERWISE ON PANEL ELEVATIONS.