CUSTOM DUAL GLAZED, TINTED SKYLIGHT BY ALUMINEX INC. (951) 353-1101 OR EQUAL (SEE MFG. SPECS. FOR INSTALATION DETAILS). PROVIDE SHOP DRAWINGS TO ARCHITECT FOR REVIEW CLASS "A" MODIFIED BUTIMEN ROOFING. SEE ROOF PLANS. INSTALL PER MANUFACTURERS SPECIFICATION EXTERIOR 3" PIPE 16 OZ. S.S. C.I. IN WALL DOWN-SPOUT 3" S.S. DOWN-SPOUT- USE SMOOTH ROUND CURVED SEGMENTS, NO CORRUGATION 1 1/2" 6 1/2" 7" 125° 1/2"1/2" NOTE: CONTRACTOR TO PROVIDE MOCK UP OF LEADER HEAD FOR ARCHITECT & OWNER REVIEW AND OWNER APPROVAL PRIOR TO INSTALLATION. SCALE: 3" = 1'-0" METAL FINIAL 5 GUARDRAIL WATERPROOFING ENLARGED