WALL FINISH; SEE WALL TYPE DETAIL 3X PRESSURE TREATED SILL PLATE SET IN SEALANT AS RECOMMENDED BY WATERPROOFING CONSULTANT 16 OZ. COPPER WEEP SCREED U.O.N. THERMAL INSULATION (SEE T-24) INTERIOR FINISH, SEE INTERIOR ELEVATIONS NOTE: - FOUNDATION SHALL BE SMOOTH BEFORE WATERPROOFING IS APPLIED. MANUFACTURER' REP. TO CERTIFY WALL IS READY TO RECEIVE WATERPROOFING. ALL WALL PENETRATIONS SHALL BE WATERPROOFED (SEE SPECS.) -SEE STRUCTURAL PLANS FOR ALL FRAMING AND FOUNDATION DETAILS EXPANSION JOINT BELOW GRADE WATERPROOFING, SEE SPEC'S (WP-2) BELOW GRADE WATERPROOFING. SEE SPECS. (WP-2) GRACE ULTRA 1' - 6" MIN. 4" MIN. 6" 2X STUD WALL PER STRUCTURAL DWGS. PER PLAN ± 6" 1' - 0" MIN. 4" GRAVEL CAPILLARY BREAK SLOPE: 6" IN 10'