METAL STUDS AT 16" OC RUNNER TRACK - ATTACH TO BOTTOM OF METAL PLATE AT 24" OC MAX (UON) AND 2" FROM ENDS. USE POWDER-DRIVEN FASTENERS AND WASHERS AT COMPOSITE DECKS AND #10 SHEET METAL SCREWS AT ALL OTHER LOCATIONS METAL STUDS AT 16" OC NON RATED RATED ACOUSTICAL NOTE: CERTAIN FIRE-RATED PARTITION HEAD ASSEMBLIES MAY REQUIRE CLOSER SPACING OF FASTENERS. REFER TO FIRE RATED TERMINATION DETAILS RATED ACOUSTICAL 24 A9.2.3 SIM 38 A9.2.3 20 A9.2.3 NON RATED 24 A9.2.3 SIM 38 A9.2.3 20 A9.2.3 RUNNER TRACK - ATTACH TO BOTTOM DECK AT 24" OC MAX (UON) AND 2" FROM ENDS. USE POWDER- DRIVEN FASTENERS AND WASHERS AT COMPOSITE DECKS AND #10 SHEET METAL SCREWS AT METAL DECKS ONLY. NOTE: CERTAIN FIRE-RATED PARTITION HEAD ASSEMBLIES MAY REQUIRE CLOSER SPACING OF FASTENERS. REFER TO FIRE RATED TERMINATION DETAILS CONTINUOUS 16 GAUGE METAL PLATE OF WIDTH TO COMPLETELY SPAN A MINIMUM OF THREE BOTTOM FLUTES. ATTACH TO BOTTOM OF DECK AT 24" OC MAX (STAGGERED 12" OC) UON AND 2" FROM ENDS. USE POWDER-DRIVEN FASTENERS AT COMPOSITE DECKS AND #10 SHEET METAL SCREWS AT METAL DECKS ONLY. PROVIDE CONT 12" WIDE (MIN) x 16 GAUGE METAL PLATE AT NON-RATED ACOUSTICAL CONDITIONS. ATTACH TO BOTTOM OF DECK AT 24" OC MAX AND STAGGER EACH SIDE. USE POWDER- DRIVEN FASTENERS AND WASHERS AT COMPOSITE DECKS AND #10 SHEET METAL SCREWS AT METAL DECKS ONLY